13
Do not set up any provisional electrical connections.
Never bypass protective devices or deactivate them.
Only hook up the machine by means of a fault-current circuit
breaker (30 mA).
The electrical connection or repairs to electrical parts of the
machine must be carried out by a certified electrician or one
of our customer service points. Local regulations – especial-
ly regarding protective measures – must be observed.
If the power cord (if available) of this machine is damaged, it
must be replaced by a specific power cord that can be
purchased from the manufacturer or customer service.
Repairs to other parts of the machine must be carried out by
the manufacturer or one of his customer service points.
Use only original spare. Accidents can arise for the user
through the use of other spare parts. The manufacturer is
not liable for any damage or injury resulting from such ac-
tion.
A
A
s
s
s
s
e
e
m
m
b
b
l
l
y
y
See page 141
S
S
t
t
a
a
r
r
t
t
-
-
u
u
p
p
Check that the machine is completely and correctly assem-
bled.
To avoid toppling, place the shredder on a firm horizontal
surface.
Do not use this machine on a paved area covered with gravel
on which thrown out material can cause injury.
The machine should only be operated in the open. Always
maintain a safe distance (at least 2 m) from walls or other
fixed objects.
Before each use, check
−
connection cables for defects (cracks, cuts, etc.).
Do not use any defective cables.
−
there are no damage at the machine (see safety instruc-
tions).
−
that all screws, nuts and bolts as well as other fasteners
are securely tightened
−
that covers, deflectors and protective shields are on their
correct position and in good working condition.
Mains connection
Compare the voltage given on the machine model plate e.g.
230 V with the mains voltage and connect the machine to the
relevant and properly earthed plug.
Only use extension cables with sufficient core cross-section.
Mains fuse
Switzerland
UK
2300 W
16 A time-lag
10 A time-lag
13 A time-lag
2800 W
16 A time-lag
13 A time-lag
Electrical mains supply impedance
When conditions in the electrical mains supply are un-favourable,
voltage reductions for short periods can occur during the process
of turning on the equipment, which can adversely affect other
equipment (e.g., the flickering of a lamp).
No breakdowns are to be expected if the maximum, electrical
mains supply impedances given in the table are met.
Power consumption P
1
(W)
Electrical mains supply
impedance Zmax (
Ω
)
2300 0.31
2800 0.31
On / Off switch
Do not use any device where the switch can not be switched
on and off. Damaged switches must be repaired or replaced
immediately by the customer service.
Switch on
Press the green button I .
Switch off
Press the red button 0 .
Restart protection in case of power
failure
In case of a power failure, the device switches off automatically
(zero-voltage initiator). To restart, press the green button again.