Model / Type
ASP 6 L
Year of construction
see last page
Splitting force
60 kN (6 t) ± 10 %
Log length
max. 1030 mm
Log diameter
min. 120 mm – max. 300 mm
Stroke
≈
500 mm
Feed speed
approx. 0.04 m/sek.
Return speed
approx. 0.17 m/sek.
Hydraulic oil (max.)
4.4 litres
Hydraulic pressure
24 MPa (240 bar)
Electric motor performance (power consumption)
P
1
2.8 kW S6 – 40%
Power supply
230 V~ 50 Hz, 16 A time-lag
Dimensions
length 840 x width 510 x height 990 / 1520 mm
Weight
approx. 103.5 kg
P
P
o
o
s
s
s
s
i
i
b
b
l
l
e
e
p
p
r
r
o
o
b
b
l
l
e
e
m
m
s
s
Before each fault clearance:
−
switch off device
−
pull out main plug
Problem Possible
cause
Remedy
Logs are not being split
properly
(insufficient splitting
performance).
⇒
The log is not positioned correctly.
⇒
The log exceeds the maximum dimensions or
the wood is too hard for the performance of
the machine.
⇒
Splitting blade does not split log.
⇒
Hydraulic pressure too low.
⇒
Release rods bent (hydraulic tappet not quite
pressed in).
⇒
Incorrect connecting lead (longer than 10 m or
too small cable cross-section).
⇒
Reposition the log correctly.
⇒
Cut the log to the required dimensions.
⇒
Sharpen splitting blade, check for burrs or notches.
⇒
Check the oil level and add more oil if necessary.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒
Arrange for manufacturer or authorised company to
adjust the rods.
⇒
Use the correct connecting lead.
Splitting column moves
unsteadily or with strong
vibrations.
⇒
Air in the circuit.
⇒
Splitting column not sufficiently lubricated or
oiled.
⇒
Check the oil level and add more oil if necessary.
⇒
Lubricate splitting column or oil with environmentally
friendly spray oil.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
Splitting column does not
move in.
⇒
Hydraulic pump defective.
⇒
To correct the problem, refer to the manufacturer or
other approved service centre.
Motor starts, but splitting
column does not move in.
Motor turns in wrong direction
To correct the problem, refer to the manufacturer or
other approved service centre.
Motor will not start.
⇒
No electrical power.
⇒
Connection cable defective.
⇒
Electric motor defective.
⇒
Check the fuse.
⇒
Replace the connection cable or have it checked by an
electrician.
⇒
To correct the problem, refer to the manufacturer or
other approved service centre.