Problem possible
cause
remedy
Logs are not being split properly
(insufficient splitting performance)
⇒
The log is not positioned correctly
⇒
The log exceeds the maximum dimen-
sions or the wood is too hard for the per-
formance of the machine
⇒
Splitting blade does not split log
⇒
Hydraulic pressure too low
⇒
Release rods bent (hydraulic tappet not
quite pressed in)
⇒
Incorrect connecting lead (longer than
10 m or too small cable cross-section)
⇒
Reposition the log correctly
⇒
Cut the log to the required dimen-
sions (page 19)
⇒
Sharpen splitting blade, check for
burrs or notches (page 22)
⇒
Check the oil level and add more oil
if necessary. (page 22)
If the problem cannot be rectified, re-
fer to the manufacturer or other ap-
proved service centre.
⇒
Arrange for manufacturer or author-
ised company to adjust the rods
⇒
Use the correct connecting lead
Log splitter does not operate, although the
motor is running
⇒
Valve does not open due to loose
connections
⇒
The operating levers or parts thereof are
bent.
⇒
Check and tighten the parts
⇒
Have bent parts repaired by the
manufacturer or a company desig-
nated by him
Motor starts, but splitting column is not
retracted
⇒
Wrong direction of rotation of motor
⇒
Check motor’s direction of rotation
and change (refer to page 19)
Motor doesn’t start
⇒
No electrical power
⇒
2-phase mode in threephase motor
⇒
Connection cable defective
⇒
Electric motor defective
⇒
Switch defective (DS)
⇒
Switch or capacitor defective
⇒
Check the fuse.
⇒
Have fuse and lead checked by
qualified electrician.
⇒
Replace the connection cable or
have it checked by an electrician.
⇒
To correct the problem, refer to the
manufacturer or other approved
service centre.
G
G
u
u
a
a
r
r
a
a
n
n
t
t
e
e
e
e
Please observe the enclosed terms of guarantee.