Here is an example of a frame with the input configured as a counter (1 sample, no history):
Octet 1
Octet 2
Octet 3-6
Octet 7
Octet
8
Octet 9
Octet 10
Octet
11
Octet
12
0xA0
(new
generation
measurement frame, no
history, 1 sample)
0x04
(channel
0, type of
measure
ment:
counter)
0x0000001
4
0x08
(channel
0,
type
of
measurement:
temperature)
0x08
0x85
0x18
(channel
1,
type
of
measurement:
temperature)
0x08
0x50
The value of the counter is equal to 0x00000014 (20 in decimal).
For temperature channel 0, the sample is 0x0885 (21.81 ° C).
For temperature channel 1, the sample is 0x0823 (20.83 ° C).
Alert measurement frame
For a high threshold exceeded on channel 0, the frame will be:
Byte 1
Byte 2
Byte 3
Byte 4
0x8D
(new generation alert frame)
0x48
(high threshold 0 threshold
exceeded,
distance
measurement)
0x29
0x38
The sample that triggered the threshold is 0x2938 (105.52 °C).