Rev.0 13/01/2020
Operator Panel | TURNTABLE - MAST
22
2.5
E01
Transpallet photocell
interrupted
-The safety photocell is activated.
-The photocell has no obstacles but
the signal does not get to the card.
-Remove the obstacle / check the mirror on the
safety photocell.
-Make sure the photocell is operating and the LED
changes status when an obstacle is inserted. If it
is not working, replace it. Check the continuity of
the cable with the signals on the panel 1+ and
8.3. Replace if broken.
E02
Rotation or running
anomaly, motor blocked
-The sensor does not read the
petals because it is too far from the
phonic wheel.
-The sensor does not read the
petals because the phonic wheel is
broken or crooked.
-The sensor does not send the
signal to the card.
-The motor seems to rotate at less
than 500 rpm for more than 2.5 s.
-The machine does not move, even
with manual controls.
-Adjust the position of the sensor compared to
the petals of the phonic wheel (distance < 2 mm).
-Fix / replace the phonic wheel.
-Check the correct operation of the sensor,
bringing it close to a metallic object. If the LED
lights up, replace the cable, if the sensor does
not work, it needs to be replaced.
-
not slippery. If the alarm occurs during slowing,
the sensor is not reading all the petals of the
phonic wheel.
-The drive or inverter does not receive
consent to start, check the wiring.
The
drive
or
inverter
is
faulty,
communicate the code shown on the
latter. For a DC motor, check the brushes.
The motor cable is not connected well, check
the wiring and tightness, even on the brake, if
present. The electromechanical brake on the
motor, if present, may not release. If this occurs,
it must be adjusted or replaced. The motor unit
may be damaged or defective; replace it.
E03
Restart after power
outage.
-The card restarted.
-The machine shut down and shows
this warning.
-Press the RESET key.
-There was a power outage and the machine
shut down and then restarted: Press the RESET
button (no power) or bell (touch).
E04
Carriage, crush
prevention limit switch
triggered
-Obstacle below the carriage.
-The E04 alarm persists without any
obstacle.
-Remove the obstacle and press RESET.
-Check the proper mechanical operation of the
micro and the crush-prevention plate. If a sensor
is broken or the plate is deformed, they must
be replaced. Check the electrical contacts and
that the signal reaches the card. If the sensor is
broken or the cable is interrupted, replace it.
Summary of Contents for EVA
Page 2: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST 2 ...
Page 4: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST II ...
Page 5: ...Atlanta Stretch S p A 1 1 1 1 1 1 1 Picture 1 ...
Page 6: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST 2 1 1 2 Picture 2 ...
Page 7: ...Atlanta Stretch S p A 3 1 1 3 Picture 3 ...
Page 12: ...Rev 0 13 01 2020 Operator Panel TURNTABLE MAST 8 1 2 1 2 1 Picture 5 ...