background image

15

OPTIONAL ACCESSORIES

Optional accessories are available for operation at 120v 60Hz or 220v 50Hz, unless specified. 
Please specify.  Consult Factory for 12v DC or other special input power requirements.

Table 5 - Optional Accessories

Optional Accessories

Available for:

Guardian

Ultraviolet Monitor - 

Analog

/

Digital

MP13A through MP49C 

Sentry

Safety Sensor

MP13A through MP49C 

Steralert

MP13A through MP49C

Audio Alarm

MP13A through MP49C 

Elapsed Time Indicator Universal Input 

MP13A through MP49C

Wall Mounting Kit 

MP13A through MP49C

Time Delay Mechanism 

MP13A through MP49C

Quantum Thermal Optimizer:

MP13A through MP49C

Solenoid Valve - Nylon (120v only)

MP13A (

1

/

2

"

) through MP22A (

3

/

4

"

)

c

MP36C (1

"

c

MP13A (

1

/

2

"

) through MP22A (

3

/

4

"

Solenoid Valve - Brass 

MP36C (1

"

MP49C (1

-

1

/

2

"

)

c

MP49C (1

-

1

/

2

"

MP13A (

1

/

2

"

MP16A (

3

/

4

"

Flow Control Valve

d

MP22A (

3

/

4

"

MP36C (1

"

MP49C (1

-

1

/

2

"

c

Valve requires 10-PSI pressure drop for satisfactory operation.

d

Unless otherwise specified PVC flow control valves are supplied. All PVC and Stainless 
Steel flow control valves are male NPT. Consult Factory for other flow control valves.

Summary of Contents for Mighty Pure MP13A

Page 1: ...pauge NY 11788 USA 631 273 0500 Fax 631 273 0771 e mail info ultraviolet com Extensive Product Information Available at Document No 98 1123E1 Revised February 2007 1994 2007 Atlantic Ultraviolet Corporation www ultraviolet com ...

Page 2: ... 16 19 Mighty Pure MODELS MP13A MP16A MP22A 16 17 Mighty Pure MODELS MP36C MP49C 18 19 USER ASSISTANCE 20 WARRANTY 20 PATENT NOTICE 20 These instructions generally describe the installation operation and maintenance of the Mighty Pure line of water purifiers Models MP13A MP16A MP22A MP36C and MP49C Questions that are not specifically answered by these instructions should be directed to the Factory...

Page 3: ...o maintain good legibility Always replace illegible safety labels Contact factory to obtain replacement safety labels SAFETY INSTRUCTIONS WARNING To guard against injury basic safety precautions should be observed including the following 1 Read and follow ALL safety instructions 2 Do not use this water purifier for other than its intended purpose as described in this manual 3 Do not alter design o...

Page 4: ...nd the exposure time The operation of the Mighty Pure is as follows 1 Water enters the purifier and flows into the annular space between the quartz sleeve and the chamber wall 2 Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp 3 The translucent sight port or optional ultraviolet monitor provides visual indication of germicidal lamp operation 4 Water leavi...

Page 5: ...ny possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purifier For added protection it is recommended that a suitable drain pan be installed under the purifier The drain pan must be plumbed to an adequate free flowing drain to prevent water damage in the event of a leak There are numerous leak ...

Page 6: ...he steps in Lamp Installation or Replacement section CAUTION Lamp and quartz sleeve are easily damaged Exercise care when installing lamp 10 Once the plumbing hook ups are made it is a good practice to disinfect the downstream plumbing between the purifier and point of use This is done by introducing chlorine into the purifier chamber a 100 ppm solution of chlorine is suggested With the chlorine i...

Page 7: ...to the rated capacity of the purifier The flow control valve is located in line prior to the water purifier and should be protected from ultraviolet exposure by the use of a 90 degree elbow fitting between the flow control valve and the water purifier 5 Audio Alarm Activated by the Ultraviolet Monitor or Safety Sensor alerts the user to any malfunction detected 6 Solenoid Valve Operated in conjunc...

Page 8: ...purifiers so equipped the Guardian Ultraviolet Monitor provides visual indication of the ultraviolet intensity through the quartz sleeve and water in the purifier chamber 2 To ensure proper operation of the water purifier regular biological testing should be performed on a schedule recommended by local public health authorities or at minimum at installation quarterly for the first year of service ...

Page 9: ...ully remove lamp socket on end now exposed 5 Next carefully slide lamp back into chamber until approximately 2 inches of the lamp is exposed on the opposite end Hold lamp and remove lamp socket 6 Lamp should now be disconnected on both ends Carefully remove lamp from chamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleeve CAUTION Lamp and quartz sleeve...

Page 10: ...OTE It is advisable to support the quartz sleeve on the opposite end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber 7 Once the quartz sleeve is removed clean with alcohol or a mild non abrasive detergent Stubborn stains usually can be removed with a dilute hydrochloric acid NOTE Follow all manufacturer s instructions and precautions when handli...

Page 11: ...quartz fragments from the interior of the chamber 8 Carefully discard all pieces of the broken quartz sleeve 9 Align the end of the replacement quartz sleeve with the gland fitting of the chamber 10 Carefully slide the quartz sleeve into the chamber guiding it through the gland fitting NOTE Use care to keep the quartz sleeve parallel to the chamber Angling the quartz sleeve in any direction could ...

Page 12: ...icing the sensor probe to work in a clean dry area 6 Once the quartz rod is removed clean with alcohol or a mild detergent and rinse with clean water Stubborn stains usually can be removed with a dilute hydrochloric acid NOTE Follow all manufacturer s instructions and precautions when handling chemicals Once the quartz rod has been cleaned handle the rod by the sides to avoid getting fingerprints ...

Page 13: ... sealing tape and reinstall Quartz sleeve fouled Clean quartz sleeve see Quartz Sleeve Cleaning or Replacement in the Maintenance section Sensor Probe if equipped Clean lens or Quartz Rod see Optional Ultraviolet lens fouled Monitor Sensor Probe Cleaning in the Maintenance section Poor purifier performance Germicidal lamp output Replace lamp as it nears its end of life EOL See AND OR Low UV intens...

Page 14: ... 50 Watts Max Operating Pressure 100 PSI 100 PSI 100 PSI 100 PSI 100 PSI Ambient Temperature 33 F 100 F 33 F 100 F 33 F 100 F 33 F 100 F 33 F 100 F Quartz Sleeve 1 1 1 1 1 Drain Plug 1 4 NPT 1 4 NPT 1 4 NPT 1 4 NPT 1 4 NPT Lamp Out Translucent Translucent Translucent Translucent Translucent Indicator Sight Port Sight Port Sight Port Sight Port Sight Port Ultraviolet Monitor Optional Optional Optio...

Page 15: ... Time Indicator Universal Input MP13A through MP49C Wall Mounting Kit MP13A through MP49C Time Delay Mechanism MP13A through MP49C Quantum Thermal Optimizer MP13A through MP49C Solenoid Valve Nylon 120v only MP13A 1 2 through MP22A 3 4 c MP36C 1 c MP13A 1 2 through MP22A 3 4 Solenoid Valve Brass MP36C 1 MP49C 1 1 2 c MP49C 1 1 2 MP13A 1 2 MP16A 3 4 Flow Control Valve d MP22A 3 4 MP36C 1 MP49C 1 1 ...

Page 16: ...16 REPLACEMENT PARTS Mighty Pure Models MP13A MP16A MP22A Figure 6 Exploded View MP13A MP16A MP22A ...

Page 17: ...A 9 Quartz Sleeve 1 15 1110A 1 15 1111A 1 15 1112A 10 Sight Port Plug 1 30 1075 1 30 1075 1 30 1075 11 Drain Plug 1 27 1216 1 27 1216 1 27 1216 12 Speed Nut 6 32 2 50 1314 13A Ballast 120v 60Hz 1 10 1070 1 10 1327 1 10 1036 13B Ballast 220v 50Hz 1 10 1074 1 10 1327 1 10 1036 14 Screw Mounting 2 50 0155 4 50 0155 4 50 0155 15 Ballast Housing 1 25 1104A 1 25 1105B 1 25 1544D 16 Screw No 8 x 3 8 long...

Page 18: ...18 REPLACEMENT PARTS Mighty Pure Models MP36C MP49C Figure 7 Exploded View MP36C MP49C ...

Page 19: ...mber 1 25 1465G4 1 25 1465F5 12 Drain Plug 1 27 1216 1 27 1216 13 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034 14 Lock Washer 1 4 4 50 1321 4 50 1321 15 Flat Washer 1 4 4 50 1317 4 50 1317 16 Ballast Housing Cover 1 25 0394A 1 25 0350A 17 Screw No 8 x 3 8 long 8 50 1323 8 50 1323 18 Speed Nut 6 32 2 50 1314 19A Ballast 120v 60Hz 1 10 1036 1 10 1091 19B Ballast 220v 50Hz 1 10 1036 1 10 0127 20 Balla...

Page 20: ...e use of or inability to use our product for any purpose whatsoever PATENT NOTICE No attempt has been made to determine the patent status of applications illustrated or described in this publi cation Inclusion in this publication of any design or method of use which may be patented is not to be con strued as promoting or sanctioning unauthorized use USER ASSISTANCE Purchased From Date Model Serial...

Reviews: