5. As soon as machine is
switched on power supply
trips.
1. Check correct ra ng of MCB.
2. Change main lead if machine doesn’t trip then
replace main lead permanently.
3. Open one connec on of hot tank if adapter
trips again then replace the hot tank.
4. Open connec on of adapter if machine
trips again replace the adapter.
5. Check the phase of main supply is not short with
body.
6. Cold water tank is full, no
dispensing of water while
pressing dispensing bu on
only premix is dispensing.
1. Check loose connec on & con nuity between
main
& DV connec ons.
controller card
2. Check connec ons of DV.
3. Replace main board.
4. Replace the DV.
7. Varia on in end cup volume.
1. Check scaling in valve & clean it.
2. Replace dispense valve.
8. Premix clo ng in canister
elbow.
1. Check exhaust fan.
2. If exhaust working, check exhaust pipe
connected properly between fan & duct.
Connect it properly. If it is not working, check
loose connec on at exhaust fan.
3. Replace exhaust fan.
9. Varia on in end cup
taste.
1. Check level of ingredient inside the canister.
Refill if it is below minimum level.
2. Check whipper motor is working or not.
If it is not working, check the voltage across motor
terminal. (a) If power supply detected replace
whipper motor. (b) If power supply not detected
check loose connec on. (c) Replace main board.
20