33
ViewPower.
cable. At this time the SO detects and installs automatically all
drivers. Now you can install ViewPower on the PC.
PC doesn’t find the
UPS.
1.
Check if the cable is properly connected
2.
Use the original cable
3.
Verify Your IP and please change if You are using
192.168.5.x subnet.
A.1.3 Battery and Fuse
Situation
Solution
Backup time
The battery backup time (sometime called battery reserve
time or battery autonomy) is the length of time the battery
will supply power to the load during a power failure. You can
check on the Appendix
Backup Time
.
Wich
type
of
battery does UPS
use?
A03-HP1102: 1 x 12VDC- 9A/h.
A03-HP1502: 2 x 12VDC- 7.2A/h.
A03-HP2202: 2 x 12VDC- 9A/h.
A03-HP3002: 2 x 12VDC- 10A/h.
How often do I
have
to
change
battery?
Atlantis recommends to replace the batteries once a year.
Where can I find
batteries?
1.
please contact Your reseller.
2.
please contact directly Atlantis.
How can I check
the Input Circuit
Breaker
(A03-
HP1102/1502)?
Under battery mode, when it¡soverload or short circuit,
UPS display UNUSUAL, then buzzer emits long sound for
30 seconds, and automatically cut off output , then it
should be reset after eliminating fault.