Page 3: ...r and or monitoring system The level measurement is achieved using a unique flexible element that is set to length without tools The gauge periodically measures the level and checks for thefts or leaks and reports these if found It also reports thetanks contents level for trending usage patterns The gauge is battery operated self contained and does not require calibration in the field ...

Page 4: ...wn in Fig 1 Each step is clarified in the text below Fig 1 No Poor No No Fit collar and seal adjust probe to length and fit to tank Activate the probe and observe indicator lights Drill 3 holes use template Does tank have pre moulded mount or holes Checkinformation has reached base Abandon install Measure and record tank height and tank volume Dip and record depth of fuel in mm Fit extended antenn...

Page 5: ...ber and is then entered during the registration process Does the tank already have an electronic gauge mounting point Many tanks now have a mount already defined and drilled If so the SmartGuard will screw straight into it If not a suitable position will have to be selected and three holes will bedrilled These are a central 25mm hole and 2 small pilot holes for self tapping screws See fig 2 If a s...

Page 6: ...6 Fig4 Fig shows the correct fitting of the probes and Fig 5 shows the correctly looped sensor weight TaÉgB Ostrog p 1 pm wo MEIN BEEK mismo a 1 1 951 I MTg mg I M ...

Page 7: ... taking a series of readings to establish the current tank level After this the GSM will be started and the red light will begin to flash At first it will flash once every second ʹ this is the unit searching for a connection to the mobile network After approximately 30 seconds it should slow down to once every four seconds This indicates that it hasregistered onto the network If it never slows dow...

Page 8: ...e taken to ensure that the cable is not damaged by forcing round bends too sharply Water If the probe is too long it will enter any water that has collected at the bottom of the tank This causes a degradation in accuracy If you do encounter a problem during installation please call Atlantis on 0330 9991100 quoting the serial number of the SmartGuard Alternatively please email www atlantistanks co ...