GLASS RECEIVER CHANNEL MUST BE INSTALLED ONTO THE WATERPROOFING BEFORE THE WALLS ARE 

TILED 

Installer

 

 When Architectural Finish is fitted to 

base.  Trim the internal leg off the wall channel to 
adequately clear the base surface.  Ensure the wall 

channel interlocks correctly with the base. 

1.

 

Choose door direction.  

 

2.

 

1 x Glass Receiver Channel 

Position the glass 
receiver channel 
over the base 
glazing channel. 
The channel will be 
located on the 
fixed panel side 
only. Use a straight 
edge and mark the 
wall to indicate where the wall channel is 
plumb. 

3.

 

Apply a silicon seal to full length of channel. 
Silicon used 
must be 
compatible with 
anodised 
aluminium as 
well as the 
waterproofing 
being used. 

 

 

 

 

4.

 

Ensure the glass 
receiver channel 
is located firmly 
over the base 
glazing channel. 
The machine 
recess in the wall 
glazing channel 
must firmly 
locate over the 
base glazing 
channel. Locate 
the framing timber. Use the 4mm drill bit to drill 
holes through the glass receiver channel. Fix 
four screws through the channel in the wall 
framing (use wall plugs if required).

 

 

 

5.

 

Apply a continuous bead of silicon to the full 
length of the channel and waterproofing, 
indicated by 
the dark line 
(inside 
channel).  

 
 

6.

 

INSTALLATION OF TOP RAIL BRACE END 
CONNECTOR CHANNELS AND SPACER 

Fix the first top rail brace end connector channel 
and spacer directly below the indicator line on 
the glass receiver channel as shown. Detail 
shown below. 

Must be accurate. 

120mm from 

top of wall 
channel to 
top of end 
connector 
channel. 

 

 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for SL3F

Page 1: ...th 2 large holes SL B 1 x 2 5mm Hex Key 1 x Plain Fixed Panel 21 B 1 x 4mm Drill Bit 1 x Handle Set SL 8 x Long Screws sq drive 1 x Roller Set 8 x Wall Plugs 2 x End Connector Channels and Spacers 1 x...

Page 2: ...icon used must be compatible with anodised aluminium as well as the waterproofing being used 4 Ensure the glass receiver channel is located firmly over the base glazing channel The machine recess in t...

Page 3: ...th the short CSK screws 9 HANDLE INSTALLATION Assemble handles as shown Use the 3mm Hex Key supplied with handle set 10 ROLLER SET ASSEMBLY TO GLASS DOOR Ensure the direction of the door is correct Fi...

Page 4: ...sealed and place into the base channel in the location as shown 17 FASTENING GLASS Secure the glass panel into the receiver channel by tightening hex screws firmly with hex key supplied Do not overtig...

Page 5: ...atible with anodised aluminium as well as the waterproofing being used 4 Ensure the glass receiver channels are located firmly over the base glazing channel The machine recess in the wall glazing chan...

Page 6: ...rovided in end connector channel Fix with the short CSK screws 9 PREPARATION FOR GLASS INSTALLATION Apply 6mm plastic packers into base glazing channels in locations as shown 10 CRITICAL SEAL Remove d...

Page 7: ...rst Seal the connection between the glass receiver channel and the base glazing channel with clear silicon prior to the installation of panel 21 B Locate the glass panel 21 B into the glazing channel...

Page 8: ...ion 201710 Revision By TD 21 BUMPER APPLICATION Apply 15mm area of primer to wall tiles in locations as shown by the dark dots Place bumpers onto primer Ensure the door slides to and meets the centre...

Reviews: