Installation Requirements

Air Quality

For optimum performance and maximum product life we recommend the use of compressed air with
a maximum dew point of +10°C (50°F). We also recommend to install an Atlas Copco refrigeration
type air dryer.

Use a separate air filter which removes solid particles larger than 30 microns and more than 90% of
liquid water. Install the filter as close as possible to the product and prior to any other air preparation
units to avoid pressure drop.

For impulse/impact tools make sure to use lubricators adjusted for these tools. Regular lubricators will
add too much oil and therefore decrease the tool performance due to too much oil in the motor.

Make sure that the hose and couplings are clean and free from dust before connecting to the tool.

Both lubricated and lubrication free products will benefit from a small quantity of oil supplied from a lu-
bricator.

Air Lubrication Guide

Brand

Air lubrication

Atlas Copco

Optimizer (1 liter) 9090 0000 04

Q8

Chopin 46

Shell

Shell Air Tool Oil S2 A 320

Compressed Air Connection

WARNING Risk of severe injury

Air under pressure can cause injury.

Always shut off the air supply when not in use or before any adjustments.

Drain the hose of air pressure and disconnect the tool from air supply when not in use or before
any adjustments.

Always use the correct hose size and air pressure for the tool.

WARNING Compressed Air

High air pressure can cause severe damage and bodily injury.

Do not exceed maximum air pressure.

Make sure that there are no damaged or loose hoses or fittings.

For correct air pressure and hose size, see the Technical Product Data on - 

https://

servaid.atlascopco.com

 or 

www.atlascopco.com

.

Make sure that the hose and couplings are clean and free from dust before connecting to the tool.

Summary of Contents for 8434124856

Page 1: ...No A1750001 Valid to Serial No A2409999 Product Instructions W2415 8434124856 WARNING Read all safety warnings and instructions Failure to follow the safety warnings and instructions may result in el...

Page 2: ...ation 6 Installation Requirements 6 Air Quality 6 Air Lubrication Guide 6 Compressed Air Connection 6 Operation 7 Ergonomic guidelines 7 Operating Instructions 7 Tightening time 7 Long sockets and ext...

Page 3: ...related to personal injury Warranty Product warranty will expire 12 months after the product is first taken into use but will in any case ex pire at the latest 13 months after delivery Normal wear and...

Page 4: ...ry of Origin please refer to the information on the product label Dimensional Drawings Dimensional Drawings can be found either in the Dimensional Drawings Archive or on ServAid Please visit http webb...

Page 5: ...lf yearly Rating and markings inspection Yearly or after 100000 tightenings Overhaul Threaded connections lubrication and tightening Service Recommendations Preventive maintenance is recommended at re...

Page 6: ...before connecting to the tool Both lubricated and lubrication free products will benefit from a small quantity of oil supplied from a lu bricator Air Lubrication Guide Brand Air lubrication Atlas Copc...

Page 7: ...ment in noisy environments Use high quality inserted tools or consumables to minimize exposure to excessive levels of vibration Minimize exposure to reaction forces When cutting A cut off wheel can ge...

Page 8: ...e the tightening time the bolted joint The tightening torque force is reduced by extension pieces and worn sockets Oversized power sockets diameter or length will overload the impact mechanism and red...

Page 9: ...below shows the recommended service interval The service must only be done by an authorized workshop or qualified service technician Daily Free speed check Air lubrication Weekly Silencer inspection S...

Page 10: ...ding paste against a surface plate and then clean thoroughly Inspection of silencer Change or clean the filters regularly Clogged filters will reduce power output Lubrication Instructions Rust Protect...

Page 11: ...Rembrandt EP2 Mobil Mobilegrease XHP 222 Shell Alvania EP2 Alvania Grease RL2 Texaco Multifak EP2 Molycote BR2 Plus Lubrication of motor parts Apply a layer of oil where indicated Lubrication of impa...

Page 12: ...Recycling Environmental Regulations When a product has served its purpose it has to be recycled properly Dismantle the product and recycle the components in accordance with local legislation Batteries...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...uthorized use or copying of the contents or part thereof is prohibited This applies in particular to trademarks model denominations part numbers and drawings Use only authorized parts Any damage or ma...

Reviews: