Change damaged parts immediately.
♦
Replace worn components in good time.
♦
Make sure that all the attached and related
equipment, such as hoses are properly
maintained.
Periodic maintenance
Once a year the lubricator must be dismantled and
all parts be cleaned and checked. This work must
be performed by authorised staff, trained for this task.
Assembly instruction
When reassembling the claw couplings on the
lubricator, apply LOCTITE® 577™ (LOCTITE is a
registered trademark of Henkel Corporation. 577 is
a trademark of Henkel Corporation).
Troubleshooting
If the lubricator is not working properly, check the
following points.
♦
Check the oil level.
♦
Check that the dimension and length of the air
hose are according to the recommendations. See
"Installation".
♦
Check for leakage around the filler plug.
♦
Make sure that there is no dirt in the oil chamber.
♦
If the lubricator function is still not satisfactory after
this procedure, contact an authorised service
workshop.
Storage
●
Clean the lubricator properly before storage, in
order to avoid hazardous substances.
●
If the lubricator is stored filled with oil, place it with
the filler plug upwards to prevent oil from leaking
out through the mouth of the air pipe.
●
Always store the lubricator in a dry place.
Disposal
A used machine must be treated and disposed of in
such a way that the greatest possible portion of the
material can be recycled and any negative influence
on the environment is kept as low as possible, and
in respect to local restrictions.