Reference
Designation
Function
2
LED, Voltage on
Indicates that the voltage is switched on.
3
Start/stop button
Keep pressed for 3 seconds to start compressor.
Press to stop compressor if running.
Use this button to go to previous screen or to end the
current action.
4
Scroll button
Use these buttons to scroll through the menu.
5
LED, Warning
Is lit if a warning condition exists.
6
LED, Service
Is lit when service is needed.
7
Enter button
Press 3 seconds to enter in menu.
Use this button to confirm the last action.
Press 5 seconds to reset alarm.
8
Scroll button
Use these buttons to scroll through the menu.
3.3
Icons used on the display
Function
Icon
Description
Stopped/Running
When the compressor is stopped, the icon stands still.
When the compressor is running, the icon is rotating.
Compressor status
Motor stopped
Running unloaded
Running unloaded (blinking for manual stop)
Running loaded
Machine control mode
Remote start/stop active
Automatic restart after
voltage failure
Automatic restart after voltage failure is active
Active protection functions
Emergency stop
Instruction book
26
2920 7119 21