Condensate drain valve on air receiver
Attention
Use only authorized parts. Any damage or malfunction caused by the use of
unauthorized parts is not covered by Warranty or Product Liability.
Apply all relevant
Safety precautions during maintenance or repair
Before carrying out any maintenance or repair work on the compressor: push the stop
button (6).
Wait until the compressor has stopped and switch off the voltage. See the
section.
Open the isolating (disconnector) switch (IG) to prevent an accidental start.
Close air outlet valve (2) and depressurize the compressor by opening the oil filler plug
(3) one turn.
Open manual condensate drain valves (4 and/or 5).
The air outlet valve (2) can be locked during maintenance or repair as follows:
• Close the valve.
• Remove the screw fixing the handle.
• Remove the handle.
• Fit the screw.
Faults and remedies
For all references given hereafter, see
,
.
Condition
Fault
Remedy
1
Compressor starts running, but
does not load after a delay time
Solenoid valve (Y1) out of order
Replace valve
Inlet valve (IV) stuck in closed
position
Have valve checked
Leak in control air pipes
Replace leaking pipe
Minimum pressure valve (Vp)
leaking (when net is
depressurised)
Have valve checked
2
Compressor air output or
pressure below normal
Air consumption exceeds air
output of compressor
Check equipment connected
Choked air inlet filter element
(AF)
Replace filter element
Solenoid valve (Y1)
malfunctioning
Replace valve
Leak in control air pipes
Replace leaking pipe
Inlet valve (IV) does not fully
open
Have valve checked
Oil separator (OS) clogged
Replace separator element
Instruction book
74
2920 7119 21