Main screen with shutdown indication, phase sequence incorrect
• Switch off the voltage, open the disconnector switch and reverse two phases of the supply
cable.
• Switch on the voltage and restart the compressor. The shutdown message will disappear
automatically when the shutdown condition has disappeared.
3.8
Service warning
Description
A service warning will appear when the service timer has reached the preset time interval.
If the service timer exceeds the programmed time interval, alarm LED (6) is blinking with a
following screen:
Blinking screen
• Press Enter button (7) to enter the main menu.
• Select <dAtA> and press Enter button (7) to enter the data menu.
• Scroll (buttons 4-8) until <d.6> and the service symbol is shown.
• Press enter button (7).
• The actual reading of the service timer is shown in <hrs>.