Step
Action
1
Push the start/stop button (6) on the controller. The compressor will unload. When the
unload time has elapsed, the compressor is stopped and the controller goes back to the
main screen.
To stop the compressor immediately in the event of an emergency, press button (S3).
See section
. After remedying the fault, unlock the button by rotating it.
Only use emergency stop button in the event of an emergency. Avoid using the button
for normal stopping of the compressor.
2
Close air outlet valve (2) and switch off the voltage to the compressor.
3
Open condensate drain valve (4) of the air receiver for a few seconds to drain any
condensate and then close the valve.
The air dryer and the air receiver remain under pressure.
The integrated filter (if installed) remains pressurised.
If maintenance or repair work is necessary, consult the
relevant safety precautions.
5.4
Taking out of operation
Air outlet valve
Condensate drain valve on air receiver
Instruction book
56
2920 7119 21