7.2
Coolers
Step
Action
1
Keep the oil cooler (Co) clean to maintain the cooling efficiency.
Also keep the cooler (Ca) clean to maintain the cooling efficiency.
2
Stop the compressor, close the air outlet valve and switch off the voltage. Remove any
dirt from the oil cooler (Co) with a fibre brush.
Open the isolating (disconnector) switch (IG).
Also remove any dirt from the air cooler (Ca). Never use a wire brush or metal objects.
Then clean using an air jet.
7.3
Safety valve
Condensate drain valve
Instruction book
2920 7119 21
67
Summary of Contents for G 15L