Oil filler plug
Testing
The valve can be tested on a separate compressed air line.
Before removing the safety valve, stop the compressor (see section
valve, switch off the voltage, open the isolating (disconnector) switch (IG), open drain valves (4)
(tank-mounted units) and the manual drain valve (5) (if fitted - on floor-mounted units) and
unscrew filler plug (3) one turn to permit any pressure in the system to escape.
If the valve does not open at the set pressure stamped on the valve, replace the valve.
No adjustments are allowed. Never run the compressor without a safety valve.
7.4
Belt set exchange and tensioning
Read the warning in the
Preventive maintenance schedule
section.
Instruction book
68
2920 7119 21
Summary of Contents for G 15L
Page 1: ...INSTRUCTION BOOK OIL INJECTED ROTARY SCREW COMPRESSORS G 18 G 22 G 15L ...