9.3
Reference conditions and limitations
Reference conditions
Air inlet pressure (absolute)
bar
1
Air inlet pressure (absolute)
psi
14.5
Air inlet temperature
˚C
20
Air inlet temperature
˚F
68
Relative humidity
%
0
Working pressure
bar(e)
Working pressure
psi
Limitations
Maximum working pressure
bar(e)
Maximum working pressure
psig
Minimum working pressure
bar(e)
4
Minimum working pressure
psig
58
Minimum ambient temperature
˚C
0
Minimum ambient temperature
˚F
32
9.4
Compressor data
G 15L
Compressor type
15k
W
100
psi
125
psi
150
psi
175
psi
7.5
bar
10
bar
13
bar
Frequency
Hz
60
60
60
60
50
50
50
Maximum (unloading) pressure UL units
bar
7.4
9.1
10.8 12.6 7.50 10
13
Maximum (unloading) pressure UL units
psig 107
132
157
182
109
145
189
Nominal working pressure
bar
6.9
8.6
10.3 12.1 7.0
9.5
12.5
Nominal working pressure
psig 100
125
150
175
102
138
181
Set-point, thermostatic valve
˚C
60
60
60
60
60
60
60
Set-point, thermostatic valve
˚F
15.6 15.6 15.6 15.6 15.6 15.6 15.6
G 18
Compressor type
18k
W
100
psi
125
psi
150
psi
175
psi
7.5
bar
10
bar
13
bar
Frequency
Hz
60
60
60
60
50
50
50
Maximum (unloading) pressure UL units
bar
7.4
9.1
10.8 12.6 7.50 10
13
Maximum (unloading) pressure UL units
psig 107
132
157
182
109
145
189
Nominal working pressure
bar
6.9
8.6
10.3 12.1 7.0
9.5
12.5
Instruction book