9.2
Settings for overload relay and fuses
Fuse size, IEC
Voltage
(V)
Frequency
(Hz)
Fuse size, Gg type
IEC
G 2
G 3
G 4
G 5
G 7
230/1
50
25A
-
-
-
-
230/3
50
16A
20A
25A
32A
40A
380/3
60
10A
-
16A
20A
25A
400/3
50
10A
12A
16A
20A
25A
Fuse size, UL/CSA
Voltage
(V)
Frequency
(Hz)
Fuse size, J or RK5 type
UL/CSA
G 2
G 4
G 5
G 7
230/1
60
25A
40A
45A
-
208/3
60
15A
25A
30A
45A
230/3
60
12A
25A
30A
45A
460/3
60
7A
12A
15A
25A
575/3
60
6A
10A
12A
15A
F21 setting, IEC
Voltage
(V)
Frequency
(Hz)
F21 setting
IEC
G 2
G 3
G 4 (DOL)
G 4 (YD)
G 5
G 7
230/1
50
20.0A
-
-
-
-
-
230/3
50
12.5A
15.5A
19.0A
11.0A
15.0A
23.3A
380/3
60
7.5A
-
12.5A
7.5A
9.0A
10.5A
400/3
50
7.0A
9.0A
11.0A
6.5A
8.5A
13.5A
F21 setting, UL/CSA
Voltage
(V)
Frequency
(Hz)
F21 setting
UL/CSA
G 2
G 4
G 5
G 7
230/1
60
20.0A
33.0A
38.0A
-
208/3
60
13.0A
20.5A
28.0A
39.0A
230/3
60
12.0A
18.0A
25.5A
35.5A
460/3
60
6.0A
9.0A
13.0A
17.5A
575/3
60
4.5A
7.5A
10.0A
13.0A
Instruction book
2920 7199 10
81
Summary of Contents for G 2
Page 1: ...INSTRUCTION BOOK OIL INJECTED ROTARY SCREW COMPRESSORS G 2 G 3 G 4 G 5 G 7 ...
Page 2: ......
Page 15: ...2 2 Air flow Pack Air flow floor mounted Pack units Instruction book 2920 7199 10 13 ...
Page 18: ...2 3 Oil system Oil system Pack Instruction book 16 2920 7199 10 ...
Page 20: ...2 4 Cooling system Pack units Instruction book 18 2920 7199 10 ...
Page 60: ...Start up Start up sheet Label on the top Instruction book 58 2920 7199 10 ...
Page 92: ......
Page 93: ......