6
Maintenance
6.1
Preventive maintenance schedule
Warning
Before carrying out any maintenance, repair work or adjustments, proceed as
follows:
• Stop the compressor.
• Switch off the voltage and open the isolating switch.
• Close the air outlet valve and open the manual condensate drain valves.
• Depressurize the compressor.
For detailed instructions, see the next sections.
The operator must apply all relevant
Warranty-Product Liability
Use only authorized parts. Any damage or malfunction caused by the use of unauthorized parts
is not covered by Warranty or Product Liability.
General
When servicing, replace all removed gaskets, O-rings and washers.
Intervals
Carry out maintenance at the interval which comes first. The local Atlas Copco Customer Center
may overrule the maintenance schedule, especially the service intervals, depending on the
environmental and working conditions of the compressor.
The "longer interval" checks must also include the "shorter interval" checks.
Preventive maintenance schedule for G 2 – G 7
Period (1)
Running hours
(1)
Action
Daily
--
Check the oil level.
After stopping, drain the condensate from the air receiver by means
of the manual drain valve (4), see section
.
--
50
Check belt tension. Adjust if necessary.
Weekly
50
Drain condensate from the oil separator vessel.
3-monthly
--
For compressors with PDX filter: check the service indicator; replace
the filter if necessary.
“
500 (2)
Inspect the air filter. Clean if necessary.
“
1000
Check the tension and the condition of the belts. Adjust if necessary.
“
1000 (2)
Inspect the oil cooler; clean if necessary.
“
“
For Full-Feature versions: inspect the condenser of the dryer; clean if
necessary.
Yearly
4000
Replace the oil filter.
Instruction book
66
2920 7199 10
Summary of Contents for G 2
Page 1: ...INSTRUCTION BOOK OIL INJECTED ROTARY SCREW COMPRESSORS G 2 G 3 G 4 G 5 G 7 ...
Page 2: ......
Page 15: ...2 2 Air flow Pack Air flow floor mounted Pack units Instruction book 2920 7199 10 13 ...
Page 18: ...2 3 Oil system Oil system Pack Instruction book 16 2920 7199 10 ...
Page 20: ...2 4 Cooling system Pack units Instruction book 18 2920 7199 10 ...
Page 60: ...Start up Start up sheet Label on the top Instruction book 58 2920 7199 10 ...
Page 92: ......
Page 93: ......