Fault
code
Fault
description
Cause
Actions
0x5114
Drive failure
(hardware)
Internal power supply tripped
Try to reset the error.
If error returns, contact Atlas Copco.
0x5115
Drive failure
(hardware)
Internal power supply tripped
0x5401
Drive failure
(hardware)
General fault detected in power
section
0x5402
Drive failure
(hardware)
General fault detected in power
section
0x6101
Drive failure
(hardware)
Eeprom read failed
Time-out communication
0x6102
Drive failure
(hardware)
Failed temperature reading of power
board
Time-out communication at
initialization
0x6103
Drive failure
(hardware)
General fault detected
0x6104
Drive failure
(hardware)
Internal checksum error detected
0x6105
Drive failure
(hardware)
Internal communication timeout
0x6106
Drive failure
(hardware)
Internal checksum error detected
0x6107
Drive failure
(hardware)
Internal communication timeout
0x6108
Drive failure
(hardware)
Internal communication timeout
0x6109
Drive failure
(hardware)
Internal checksum error detected
0x610A
Drive failure
(hardware)
Internal communication overload
0x610B
Drive failure
(hardware)
Internal control overload
0x610C
Drive failure
(hardware)
CAN communication time-out
Check CAN-cable connection
between Elektronikon and converter.
Check position of the CAN
termination switch at both sides of the
CAN cable. Both should be OFF.
0x610D
Drive failure
(hardware)
Firmware not compatible
Try to reset the error.
If error returns, contact Atlas Copco.
0x610E
Drive failure
(hardware)
Not able to identify power board
0x610F
Drive failure
(hardware)
Not able to identify IGBT module
0x6110
Drive failure
(hardware)
Power board not compatible with IGBT
modules
Instruction book
112
API480496
Summary of Contents for GA 37 VSD
Page 1: ...INSTRUCTION BOOK API480496 GA 37 VSD ...
Page 2: ......
Page 14: ...Front view GA 37 VSD up to GA 45 VSD Workplace Full Feature Instruction book 12 API480496 ...