service level for a monitored component has been exceeded. Carry out the service actions of the
indicated plans or replace the component and reset the relevant timer, see section
.
6.6
Stopping
Control panel
Control panel Elektronikon™ Graphic
Procedure
Step
Action
-
Press stop button (9). Automatic operation LED (8) goes out and the compressor stops after
30 seconds of unloaded operation.
-
To stop the compressor in the event of an emergency
, press emergency stop button (10).
Alarm LED flashes (7).
On compressors with an Elektronikon® Graphic controller:
• Remedy the problem cause and unlock the button by pulling it out.
• Navigate to the Stop icon on the display by means of the navigation keys (3/4) and press
the Select key.
Press Reset.
Do not use the emergency stop button for normal stopping!
-
Close the air outlet valve.
-
Press the test button on top of the electronic water drain(s) (if supplied) to the depressurize the
piping between air receiver and outlet valve, next open the manual drain valve (Dm). See
section
.
Switch off the voltage.
6.7
Taking out of operation
Warning
The operator must apply all relevant
.
Instruction book
API480496
91
Summary of Contents for GA 37 VSD
Page 1: ...INSTRUCTION BOOK API480496 GA 37 VSD ...
Page 2: ......
Page 14: ...Front view GA 37 VSD up to GA 45 VSD Workplace Full Feature Instruction book 12 API480496 ...
Page 127: ......