7
Maintenance
7.1
Preventive maintenance schedule
Warning
Control panel
Always apply all relevant
Before carrying out any maintenance, repair work or adjustments, do as follows:
• Stop the compressor.
• Close the air outlet valve and press the test button on top of the electronic water
drain(s) until the air system between air receiver and outlet valve is fully
depressurized.
• Press the emergency stop button (10).
• Switch off the voltage. Open and lock the isolating switch.
• Depressurize the compressor by opening the oil filler plug one turn.
Before electrical maintenance
• Wait for at least 10 minutes before starting any electrical repairs as dangerous
high voltage remains on the capacitors of the start and speed regulation unit
during some minutes after switching off the voltage.
• Always switch off the voltage. Only pressing the emergency stop button is not
sufficient to make the compressor voltage free.
• If the machine is equipped with an automatic restart after voltage failure function
and if this function is active, be aware that the machine will restart automatically
when the power is restored if it was running when the power was interrupted.
Warranty - Product Liability
Use only authorised parts. Any damage or malfunction caused by the use of unauthorised parts
is not covered by Warranty or Product Liability.
Service kits
For overhauling or carrying out preventive maintenance, service kits are available (see section
).
Instruction book
API480496
93