Problem solving
Warning
Always apply all relevant
Before carrying out any maintenance, repair work or adjustment, press the stop button,
wait until the compressor has stopped and close the air outlet valve.
Open the manual drain valve(s).
Press the emergency stop button and switch off the voltage. Open and lock the isolating
switch.
Depressurise the compressor by opening the oil filler plug one turn.
For location of components: see sections
,
and
.
The air outlet valve can be locked during maintenance or repair as follows:
• Close the valve.
• Remove the screw fixing the handle with the wrench delivered with the
compressor.
• Lift the handle and turn it until the slot of the handle fits over the blocking edge on
the valve body.
• Fit the screw.
Before electrical maintenance
• Wait for at least 10 minutes before starting any electrical repairs as dangerous
high voltage remains on the capacitors of the start and speed regulation unit
during some minutes after switching off the voltage.
• Always switch off the voltage. Only pressing the emergency stop button is not
sufficient to make the compressor voltage free.
• If the machine is equipped with an automatic restart after voltage failure function
and if this function is active, be aware that the machine will restart automatically
when the power is restored if it was running when the power was interrupted.
Faults and remedies, compressor
On compressors equipped with an Elektronikon® Graphic controller, if the alarm LED is lit or
flashes, consult sections
.