117
Instruction book
9096 3313 00
service plan interval has been exceeded or if a service level for a monitored component has been exceeded.
Carry out the service actions of the indicated plans or replace the component and reset the relevant timer, see
section
Service menu.
7.7 Stopping
Elektronikon regulator
Procedure
7.8 Taking out of operation
Warning
Control panel Eledtronikon Graphic
Step
Action
-
Press stop button (9). Automatic operation LED (8) goes out and the compressor stops after
30 seconds of unloaded operation.
-
To stop the compressor in the event of an emergency,
press emergency stop button (10).
Alarm LED flashes (7).
On compressors with an Elektronikon® Graphic controller:
•
Remedy the fault and unlock the button by pulling it out.
•
Navigate to the Stop icon on the display by means of the navigation keys (3/4) and
press the Select key.
Press reset.
Do not use emergency stop button (10) for normal stopping!
See also section
Emergency stop button
.
-
Close air outlet valve (AV), see section
Introduction.
-
On water-cooled compressors:
•
Close the cooling water inlet valve.
•
If freezing temperatures can be expected, drain the cooling system completely.
The operator must apply all relevant
Safety precautions.
Summary of Contents for GA 55+
Page 1: ...GA 55 GA 75 GA 90 Instruction book Atlas Copco Oil injected rotary screw compressors ...
Page 2: ......
Page 4: ......
Page 9: ......
Page 96: ...96 Instruction book 9096331300 6 Installation 6 1 Dimension drawings Centre of gravity ...
Page 98: ...98 Instruction book 9096331300 6 2 Installation proposal Compressor room example ...
Page 109: ...109 Instruction book 9096331300 ...
Page 123: ...123 Instruction book 9096331300 Procedure Oil system components Oil drain plugs ...
Page 145: ...145 Instruction book 9096331300 Notes ...
Page 146: ...146 Instruction book 9096331300 Notes ...
Page 147: ...147 Instruction book 9096331300 Notes ...
Page 148: ......
Page 149: ......