132
Instruction book
9096 3313 00
11 Technical data
11.1 Readings on display
Display of the Elektronikon®
Important
The readings mentioned below are valid under the reference conditions (see section
Reference conditions and limitations).
Reference
Reading
Air outlet pressure
Modulates between programmed unloading and loading pressures.
Compressor element
outlet temperature
For air-cooled units: approx. 60 °C above cooling air inlet temperature For
water-cooled units: approx. 60 °C above cooling water inlet temperature.
Dewpoint temperature
See section
Compressor data.
Pressure difference over
oil separator
Below 1 bar.
Cooling water outlet
temperature
Below 50 °C.