86
Instruction book
9096 3313 00
Condition
Fault
Remedy
3
Water is present on the floor
around the compressor (and on
the compressor frame).
A connection is leaking. A
push-in coupling is leaking.
Stop the compressor. Open the side
panel and inspect the OSCi (remove
the covers from the vessels). Verify
that the drain valves (4 - Condensate
flow scheme and View of OSCi) at the
bottom of vessel 1 and 2 are closed.
Drain the OSCi and try to fix the
problem.
If a connection is leaking, take out the
corresponding tube and cut it off
straight 1 cm further. If that doesn't
help, order a new connection (spare
part).
No connections are leaking but
the water level in vessel 2 or 3
reaches the top of the vessel.
Verify that the outlet tube is positioned
everywhere below the outlet
connection on vessel 3 (View of OSCi
outlet) and is not blocked off
somewhere (also outside the
compressor). If structural constraints
require the outlet pipe to be above the
level of the outlet connection on vessel
3, install a pump (that can run dry) in
the outlet circuit.
If the above requirements are
met and the water level
reaches the top of vessel 2, or
if the water level in vessel 1
reaches at least the sight glass.
Remove all the filters, clean the OSCi
and order a filter service kit to replace
the filters. Verify the vessel separator
and scavenge line flow, and replace
them in case of abnormalities.
If an overflow is to be avoided at all
costs, please ask your service centre
to program the Elektronikon® to shut
down the compressor when an
overflow alarm is generated.
4
The time frame that it takes for
the turbidity of the test sample
to be above the limit of the
reference sample is much
shorter than expected, based
on the estimated filter lifetime.
See also section
Technical
data.
When servicing the filters, the following
test procedure must be carried out
after draining the vessels: Disconnect
the OSCi air tube at the bottom of
vessel 2, and guide the airtube through
the baffles to outside the compressor
canopy. Close all compressor panels,
start the compressor and wait for
loading condition. Check if airflow is
coming out of the airtube (must be
between 450 and 1000 l/h) (between
15.9 and 35.3 cu ft/h). Stop the
compressor.
Summary of Contents for GA 55+
Page 1: ...GA 55 GA 75 GA 90 Instruction book Atlas Copco Oil injected rotary screw compressors ...
Page 2: ......
Page 4: ......
Page 9: ......
Page 96: ...96 Instruction book 9096331300 6 Installation 6 1 Dimension drawings Centre of gravity ...
Page 98: ...98 Instruction book 9096331300 6 2 Installation proposal Compressor room example ...
Page 109: ...109 Instruction book 9096331300 ...
Page 123: ...123 Instruction book 9096331300 Procedure Oil system components Oil drain plugs ...
Page 145: ...145 Instruction book 9096331300 Notes ...
Page 146: ...146 Instruction book 9096331300 Notes ...
Page 147: ...147 Instruction book 9096331300 Notes ...
Page 148: ......
Page 149: ......