Maximum altitude operation
ft
3281 ft above sea level
On water-cooled units also:
Maximum cooling water outlet temperature
˚C
50
Maximum cooling water outlet temperature
˚F
122
Maximum cooling water inlet pressure
bar(e)
5
Maximum cooling water inlet pressure
psig
72.52
11.5 Compressor data
Note
All data specified below are valid at reference conditions; see section
.
GA 75 VSD
Unit
13 bar
175 psi
13 bar
175 psi
13 bar
175 psi
Frequency
Hz
50
60
50
60
50
60
Number of compression stages
1
1
1
Normal effective working pressure
bar(e)
7
9.5
12.5
Normal effective working pressure
psig
102
138
181
Maximum effective working pressure,
Workplace
bar(e)
7.5
10
13
Maximum effective working pressure,
Workplace
psig
109
145
189
Maximum effective working pressure,
Workplace Full-Feature
bar(e)
7.25
9.75
12.75
Maximum effective working pressure,
Workplace Full-Feature
psig
105
141
185
Maximum motor shaft speed
rpm
2975
2500
2175
Minimum motor shaft speed
rpm
600
600
600
Temperature of air leaving outlet valve
(approx.), Workplace
˚C
30
30
30
Temperature of air leaving outlet valve
(approx.), Workplace
˚F
86
86
86
Temperature of air leaving outlet valve
(approx.), Workplace Full-Feature
˚C
24
24
24
Temperature of air leaving outlet valve
(approx.), Workplace Full-Feature
˚F
75
75
75
Nominal motor rating
kW
75
75
75
Nominal motor rating
hp
100
100
100
Refrigerant type, Workplace Full-Feature
R404a
R404a
R404a
Instruction book
104
2920 1634 04