GA Full-Feature
Procedure
1. Stop the compressor and close the air outlet valve. Depressurize the air outlet system by pressing the test
button on top of the Electronic Water Drain(s). Switch off the voltage.
• Install one OSD unit for Workplace compressors.
• Install two OSD units for Full-Feature compressors.
See section
for location of the drain(s) and Electronic Water Drain(s).
2. Loosen the condensate drain tube of the compressor condensate trap from its coupling (Da).
Also loosen the condensate drain tube of the dryer condensate trap from its coupling (Da1).
3. Position the separator kit as shown and fix it with bolts (1).
4. Fix support (2) with bolt(s) (3).
5. Connect the loose drain tube from condensate drain (Da) to the connection of pre-filter (4).
Connect the loose drain tube from condensate drain (Da1) to the connection of pre-filter (4).
6. Remove the coupling (Da) and install the couplings delivered with the separator kit.
Connect water tube (5) to the rear side of coupling (Dc). Lead the condensate outlet flexible from coupling
(Dc) towards the condensate drain system.
For Workplace Full-Feature compressors repeat this action by removing coupling (Da1) and install and
connect coupling (Dc1) from the second OSD.
7. Remove the cover (6) and fill vessel (7) with water until the water flows through the water outlet of the
OSD (5). Reinstall the cover.
4.3
Operating and maintenance instructions
Safety precautions
Before carrying out any maintenance, repair work or adjustments, proceed as
follows:
•
Stop the compressor.
•
Close the air outlet valve and press the test button on top of the electronic
water drain until the air system between air receiver and outlet valve is fully
depressurized.
•
Press the emergency stop button.
•
Switch off the voltage.
•
Depressurize the compressor.
For detailed instructions, see
.
The operator must apply all relevant
.
Instruction book
2920 1634 04
59