3.24 Saved data menu
Control panel
Function
To call up some compressor data saved by the regulator. These data are:
• Last shut-down data
• Last emergency stop data
Procedure
Starting from the Main screen:
• Press the key ‘Menu’ (F1).
• Press the arrow down key (1) until the option ‘Saved Data’ is followed by a horizontal arrow.
• Press the tabulator key (2) to activate the menu.
• The list of last shut-down and emergency stop cases is shown.
• Scroll through the items to select the desired shut-down or emergency stop item.
• Press tabulator key (2) to find the date, time and other data reflecting the status of the compressor when
the last shut-down occurred.
3.25 Programmable settings
Compressor/motor
Minimum
setting
Factory
setting
Maximum
setting
Set-point 1/2
GA VSD Workplace
bar(e)
4
7
13
GA VSD Workplace
psig
58
100
188
GA VSD Full-Feature
bar(e)
4
7
12.8
GA VSD Full-Feature
psig
58
100
186
Indirect stop level
bar
0.1
0.3
1
Indirect stop level
psi
1.45
4.35
14.5
Direct stop level
bar
0.3
1
1.5
Direct stop level
psi
4.35
14.5
21.8
Proportional band
%
6
10
15
Instruction book
2920 1634 04
53