9
Adjustments and servicing procedures
9.1
Air filter
Location of air filter
Air filter, GA 75 VSD and GA 90 VSD
Recommendations
1. Never remove the element while the compressor is running.
2. For minimum down-time, replace the dirty element by a new one.
3. Discard the element when damaged.
Procedure
1. Stop the compressor. Switch off the voltage.
2. Release the snap clips of air filter (AF) and remove the dust trap and the air filter element. Clean the trap.
Discard the filter element.
3. Fit the new element and the trap.
4. Reset service indicator (1) by pushing the knob in the extremity of the body.
5. Reset the air filter service warning.
After carrying out all service actions in the relevant ‘Service Plan’, reset the service warning; see section
9.2
Coolers
Cleaning
Keep the coolers clean to maintain efficiency.
On air-cooled compressors:
• Stop the compressor, close the air outlet valve and switch off the voltage.
• Cover all parts under the coolers.
Instruction book
96
2920 1634 04