Type
V
Approval
Recommended wire section (AWG)
Pack
Full Feature
GA 5
200
CSA/UL
8
8
GA 5
200/230/460
CSA/UL
8
8
GA 5
575
CSA/UL
14
12
GA 7
200
CSA/UL
8
6
GA 7
200/230/460
CSA/UL
8
6
GA 7
575
CSA/UL
12
10
GA 11
200
CSA/UL
4
4
GA 11
200/230/460
CSA/UL
4
4
GA 11
575
CSA/UL
10
10
11.3 Settings for overload relay and fuses
Overload relay and fuses
Type
V
Approval
Overload Relay
Pack
Overload Relay
Full Feature
MAX
Setting (A)
MAX
Setting (A)
GA 5
200
IEC
40
32
40
39
GA 5
230
IEC
28
28
40
32
GA 5
380
IEC
20
16
25
19
GA 5
400
IEC
20
16
25
19
GA 5
400 + N
IEC
20
16
25
21
GA 5
460
IEC
20
15
20
17
GA 5
500
IEC
16
14
20
16
GA 7
200
IEC
50
42
50
48
GA 7
230
IEC
40
36
50
41
GA 7
380
IEC
25
21
32
24
GA 7
400
IEC
25
21
32
24
GA 7
400 + N
IEC
25
21
32
26
GA 7
460
IEC
25
19
25
21
GA 7
500
IEC
20
19
25
20
GA 11
200
IEC
63
60
80
68
GA 11
230
IEC
63
52
63
59
GA 11
380
IEC
32
30
40
34
GA 11
400
IEC
32
30
40
34
Instruction book
162
2920 7090 51
Summary of Contents for GA11
Page 1: ...Atlas Copco Oil injected rotary screw compressors GA 5 GA 7 GA 11 Instruction book ...
Page 2: ......
Page 24: ...Service diagram Designations Instruction book 22 2920 7090 51 ...
Page 120: ...GA 5 up to GA 11 Pack on 270 l air receiver Instruction book 118 2920 7090 51 ...
Page 121: ...GA 5 up to GA 11 Full Feature Floor mounted Instruction book 2920 7090 51 119 ...
Page 122: ...GA 5 up to GA 11 Full Feature on 270 l air receiver Instruction book 120 2920 7090 51 ...
Page 123: ...GA 5 up to GA 11 Pack on 500 l air receiver Instruction book 2920 7090 51 121 ...
Page 177: ......