Procedure
Step
Action
1
Stop the compressor, close the air outlet valve and switch off the voltage. Wait a few
minutes and depressurise by unscrewing plug (4) only one turn to permit any pressure in
the system to escape.
2
Use an oil pan to avoid possible oil spillage. Unscrew oil filters (3) only one turn and wait
a few minutes to let the oil of the filter flow back into the oil separator. Remove the oil filters.
3
Clean the filter seats on the manifold. Oil the gaskets of the new filters and screw the filters
into place until the gaskets contact their seats. Then tighten by hand.
4
Tighten plug (4).
5
Reset the message and service timer:
•
Press the “Menu” key (3).
•
Press key (1) until “Service” is followed by an arrow pointing to the right. Activate the
menu by pressing key (2).
•
Press key (1) until “Oil filter” is followed by an arrow pointing to the right. Activate the
menu by pressing key (2).
•
Press the “Reset” key (3); the timer is reset to 0.
6.6
Storage after installation
Procedure
Run the compressor, e.g. twice a week, until warm. Load and unload the compressor a few times to operate
the components of the unloading/loading system.
If the compressor is going to be stored without running from time to time, protective
measures must be taken. Consult the Atlas Copco Customer Centre.
6.7
Service kits
General
Service kits comprise all parts needed for servicing components and offer the benefits of genuine Atlas Copco
parts while keeping the maintenance budget low. All service kits are indicated in the relevant Parts Lists.
Atlas Copco Roto-Inject Fluid
Roto-Inject Fluid can be ordered in the following quantities:
• 20-litre can: 2901 0522 00
• 209-litre drum: 2901 0045 01
See the section
Instruction book
2920 1475 06
101
Summary of Contents for GA110
Page 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Page 2: ......
Page 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Page 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Page 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Page 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Page 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Page 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Page 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Page 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Page 133: ...Instruction book 2920 1475 06 131 ...
Page 134: ......
Page 135: ......