arrow. Press the key “Modify”, the first two digits of the command start blinking. Modify as required
using the scroll keys, i.e. in the example above change “18” into “17” using the arrow up key (1).
• If necessary, press the tabulator key (2) to go to the next field to be modified, the minutes indication and
the start/stop/pressure band indication.
• Press the key “Program” to program the new command or the key “Cancel” to quit without reprogramming.
Adding a command at the end of an existing list
• Starting from the Main screen, press the key “Menu” (F1), press the arrow down key until the option
“Modify Parameters” is followed by a horizontal arrow.
• Activate the menu by pressing the tabulator key (2).
• Use the arrow down key (1) to scroll until the option “Clock Function” is followed by a horizontal arrow.
Press the tabulator key, following screen appears:
“Clock Function”
“Not Activated”
.
“Menu”
“Modify”
“Delete”
F1
F2
F3
Suppose the command to stop the compressor at 18:00 must be added to the list of Monday
• Press the tabulator key (2), following screen appears:
“Monday”
“Tuesday”
“Wednesday”
“Menu”
“Delete”
F1
F2
F3
• Scroll through the display until “Monday” is followed by a horizontal arrow. Press the tabulator key (2).
Scroll through the compressor start/stop/pressure band commands until the first empty command line is
indicated by the horizontal arrow.
• Press the key “Modify”; the first two digits start blinking. Enter “18:00 Compressor Stop” using the scroll
keys (1) to modify a field and the tabulator key (2) to jump from one field to another.
• Press the key “Program” to program the new command or the key “Cancel” to quit without reprogramming.
Adding a command between two existing commands
Suppose the command “17:00 Pressure Band 2” must be added to the following list:
• 06:00 Start Compressor
• 06:00 Pressure Band 1
• 18:00 Stop Compressor
The regulator does not allow to enter a new command which is situated before the last command in the list
timewise.
Scroll through the display until the command before which the new command must be entered is followed
by a horizontal arrow (in the example above: “18:00 Stop Compressor”) and press the key “Modify”.
Change this command to the new command (in the example above “17:00 Pressure Band 2”)
Instruction book
44
2920 1475 06
Summary of Contents for GA110
Page 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Page 2: ......
Page 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Page 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Page 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Page 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Page 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Page 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Page 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Page 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Page 133: ...Instruction book 2920 1475 06 131 ...
Page 134: ......
Page 135: ......