6
Maintenance
6.1
Preventive maintenance schedule
Warning
Before carrying out any maintenance, repair work or adjustment, proceed
as follows:
•
Stop the compressor.
•
Press emergency stop button (S2).
•
Close the air outlet valve and open the manual condensate drain valves.
•
For compressors equipped with electronic water drains, press the test
buttons on top of the electronic drains until the air system between the air
receiver and the outlet valve is fully depressurised.
•
Switch off the voltage.
•
Open and lock the isolating switch.
The operator must apply all relevant
Warranty - Product Liability
Use only authorised parts. Any damage or malfunction caused by the use of unauthorised parts is not covered
by Warranty or Product Liability.
General
When servicing, replace all removed gaskets, O-rings and washers.
Preventive maintenance schedule
Period
Running hours
Operation
Daily
8
Check readings on display.
Daily
8
Check that condensate is discharged during loading.
Daily
8
Check oil level. Before starting, the level should be in the middle of the
sight-glass.
Weekly
--
Drain condensate from the air receiver, if installed
Weekly
50
On compressors equipped with an OSD, check the oil level in the oil
collectors. If necessary, empty the collectors and take the oil to the
local collection service. Keep the covers of the vessels in place to
prevent possible evaporation.
3-Monthly
--
On compressors equipped with an OSD, remove, dismantle and clean
the float valve of the condensate traps.
3-Monthly
--
Clean compressor.
3-Monthly
--
Check for possible leaks.
3-Monthly
500
Check the coolers; clean them if necessary. See the section
3-Monthly
--
Remove air filter elements and inspect
Yearly
--
Have safety valve tested
Instruction book
90
2920 1475 06
Summary of Contents for GA110
Page 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Page 2: ......
Page 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Page 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Page 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Page 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Page 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Page 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Page 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Page 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Page 133: ...Instruction book 2920 1475 06 131 ...
Page 134: ......
Page 135: ......