Period
Running hours
Operation
Yearly
--
Have all flexibles inspected
Yearly
4000
Replace oil filters
Yearly
4000
If Roto-Inject Fluid is used, change oil
Yearly
8000
If Roto-Xtend Duty Fluid is used, change oil
2-Yearly
8000
Have oil separator element replaced
When displayed
--
Carry out service action according to the displayed service plans.
When operating in a dusty atmosphere, inspect the air filters more frequently.
Use always Atlas Copco filters.
The separator element must also be replaced when the pressure difference over the element
exceeds 0.8 bar (12 psi). Check the pressure drop when the compressor is running loaded
and preferably with a stable working pressure.
Damaged flexibles must be replaced immediately.
Service agreements
Atlas Copco Customer Centres have a range of service agreements to suit your needs:
• An Inspection Plan
• A Preventive Maintenance Plan
• A Total Responsibility Plan
Contact your Customer Centre to set up a tailor-made service agreement. It will ensure optimum operational
efficiency, minimise downtime and reduce the total life cycle costs.
Service plan
A number of service operations are grouped (called Level A, Level B, Level C...). Each level stands for a
number of service actions to be carried out at the time intervals programmed in the Elektronikon regulator.
When a level is reached, a message will appear on the screen. After carrying out all service actions, the interval
timers must be reset using the “Reset” key in the “Service” menu. Consult your Atlas Copco Service Centre.
6.2
Motors
Warning
Stop the compressor and switch off the voltage. The operator must apply all relevant
Never mix greases of different brands or types.
Fan motors
The bearings of the fan motors are greased for life. The bearings of the fan motor must be replaced after 25000
operating hours.
Instruction book
2920 1475 06
91
Summary of Contents for GA110
Page 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Page 2: ......
Page 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Page 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Page 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Page 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Page 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Page 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Page 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Page 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Page 133: ...Instruction book 2920 1475 06 131 ...
Page 134: ......
Page 135: ......