Oil separating device
Step
Action
1
Remove the cover and fill vessel (1) with water to the level of water outlet (2).
2
Refit the cover.
Start up
Step
Action
1
(see the section Cooling and condensate system)
2
Switch on the voltage.
3
Start the compressor and stop it immediately. Check the rotation direction of the drive
motor while the motor is coasting to a stop.
4
If the rotation direction is wrong, press the emergency stop button, switch off the voltage
and reverse two incoming electric lines.
The correct direction of rotation is indicated for the drive motor by an arrow on the gear
casing and for the fan motors by arrows on the motor housings.
4
Run the compressor for a few minutes and check that it is operating normally.
5.2
Before starting
Warning
The operator must apply all relevant
Safety precautions
.
If the water system was drained, make sure the drain valves are closed.
Instruction book
2920 1475 06
81
Summary of Contents for GA110
Page 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Page 2: ......
Page 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Page 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Page 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Page 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Page 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Page 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Page 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Page 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Page 133: ...Instruction book 2920 1475 06 131 ...
Page 134: ......
Page 135: ......