“Compressor outlet”
7.5 bar (109 psi)
.
“Automatically loaded”
“Menu”
“Unload”
F1
F2
F3
Automatic operation
Normally, the compressor runs in automatic operation, i.e. the electronic regulator loads, unloads, stops and
restarts the compressor automatically. LED (8) is then lit.
Manually unloading
Press “Unload” key (F3), LED (8) goes out. The message “Manually Unloaded” appears on the display. The
compressor remains running unloaded unless it is loaded again manually.
Manually loading
Press “Load” key (F3), LED (8) lights up. The command “Load” does not force the compressor into loaded
condition, but it will switch the compressor to automatic operation again; the compressor will be loaded if
the air net pressure drops below the programmed level.
5.7
Stopping
Important
After pressing stop button (9), the compressor will run unloaded for 30 seconds. The
compressor stops after this period. A start command during this period is ignored.
After stopping, the compressor is prevented from restarting within a programmable time
(20 seconds). A start command given during this minimum stop time will be memorised;
the automatic operation LED lights up. The compressor will start when the minimum stop
time has elapsed.
Instruction book
2920 1475 06
87
Summary of Contents for GA110
Page 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Page 2: ......
Page 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Page 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Page 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Page 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Page 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Page 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Page 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Page 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Page 133: ...Instruction book 2920 1475 06 131 ...
Page 134: ......
Page 135: ......