Control panel
Control panel of Elektronikon MkIV regulator
Reference
Name
1
Press stop button (9). LED (8) goes out. The message “Programmed stop” appears. The
compressor runs unloaded for 30 seconds and then stops.
2
To stop the compressor in the event of an emergency, press button (S2). Alarm LED (7)
blinks. After remedying the fault, unlock the button by pulling it out
3
Close the air outlet valve.
4
Open the condensate drain valves.
For compressors equipped with electronic water drains, press the test buttons on top of
the electronic drains until the air system between the air receiver and the outlet valve is
fully depressurised.
5
Switch off the voltage.
6
On water cooled compressors, close the water shut-off valves.
7
On water cooled compressors, if the compressor is installed in a room where freezing
temperatures are expected, drain the cooling system by opening the drain valves in the
water inlet and outlet pipes (customer's installation).
5.8
Taking out of operation
Disconnecting the compressor
At the end of the service life of the compressor, proceed as follows:
Step
Action
1
Stop the compressor and close the air outlet valve.
2
Switch off the voltage and disconnect the compressor from the mains.
3
Depressurize the compressor by opening the drain valve and loosening the oil filler plug
one turn.
For compressors equipped with electronic water drains, press the test buttons on top of
the electronic drains until the air system between the air receiver and the outlet valve is
fully depressurized.
Instruction book
88
2920 1475 06
Summary of Contents for GA110
Page 1: ...GA 90 GA 110 GA 132 GA 160 GA 200 GA 250 GA 315 ...
Page 2: ......
Page 17: ...Flow diagram of GA200 GA250 and GA315 60 Hz Instruction book 2920 1475 06 15 ...
Page 30: ...Menu flow for GA 90 up to GA 315 simplified example Instruction book 28 2920 1475 06 ...
Page 57: ...Dimension drawing of GA90 110 water cooled Instruction book 2920 1475 06 55 ...
Page 60: ...Dimension drawing of GA200 250 and GA315 60 Hz air cooled Instruction book 58 2920 1475 06 ...
Page 64: ...Compressor room example of GA 90 up to GA 160 water cooled Instruction book 62 2920 1475 06 ...
Page 76: ...Suspended solids Non soluble particles size 1 mm 10 ppm Instruction book 74 2920 1475 06 ...
Page 98: ...Filler and drain plugs on GA 200 up to GA 500 compressors Instruction book 96 2920 1475 06 ...
Page 102: ...Position of oil filter on GA 200 up to GA 500 Instruction book 100 2920 1475 06 ...
Page 133: ...Instruction book 2920 1475 06 131 ...
Page 134: ......
Page 135: ......