10.5 Taking out of operation
Warning
The operator must apply all relevant
.
Procedure
Step
Action
1
Stop the compressor and close the air outlet valve.
2
Open the manual condensate drain (if provided).
3
Switch off the voltage and disconnect the compressor from the mains.
4
Unscrew the oil filler plug only one turn to permit any pressure in the system to escape.
5
Shut off and depressurize the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
6
Drain the oil.
7
Drain the condensate circuit and disconnect the condensate piping from the condensate net.