12
Adjustments and servicing procedures
12.1 Drive motor
General
Keep the outside of the electric motor clean for efficient cooling. If necessary, remove dust with a brush
and/or compressed air jet.
Bearing maintenance
The motor bearings do not need to be regreased during their normal service life.
12.2 Air filter
Location of air filter
Recommendations
1. Never remove the filtration element while the compressor is running.
2. For minimum downtime, replace the dirty element by a new one.
3. Discard the element when damaged.
Procedure
1. Stop the compressor. Switch off the voltage.
2. Remove the side panel.
3. Remove the cover of air filter (AF) by turning it anti-clockwise. Remove the filter element. If
necessary, clean the cover.
4. Fit the new element and the cover.
5. Reset the air filter service warning.
For compressors equipped with an Elektronikon® regulator, see section
For compressors equipped with an Elektronikon® Graphic regulator, see section
.
Instruction book