• This screen shows the load delay time (10) and the unit (s= seconds). To modify this value press the
Enter button (13) (a password may be required).
• The value starts blinking and Scroll buttons (12) can be used to modify the value.
• Press the Enter button (13) to program the new value.
The minimum and maximum value depends on the parameters.
7.28 Calling up modifying minimum stop time
Starting from the Main screen:
• Press the Scroll button (12) until <P.12> and the motor pictograph is shown and press the Enter
button (13):
• This screen shows the minimum stop time (20) and the unit <s> (seconds).
• To modify this value press the Enter button (13). The value starts blinking and Scroll buttons (12) can
be used to modify this value.
• Press Enter button (13) to program the new value.
The minimum and maximum values depend on the parameters.
7.29 Activating password protection
Important settings such as the setting of the service timer, pressure band setting, control mode settings,...
can be protected by a password.
Starting from the Main screen:
• Press Scroll buttons (12) until <P.13> is shown and press Enter button (13):
• Password (<PASS>) appears on the screen. Press the Enter button (13).
Instruction book
50
2920 7140 90