• The screen shows the password status (ON (<On>) or OFF (<OFF>). Press Enter button (13) to
modify.
• Change the value with Scroll buttons (12).
• Select <On> and press Enter button (13).
• Enter the new password and press Enter button (13) to confirm.
• Enter the password again and press Enter button (13) to confirm.
• <On> appears on the display. Press reset key to return to the parameter screen.
Lost passwords can not be recovered. Save the password carefully.
7.30 Activate load/unload remote pressure sensing
Starting from the Main screen:
• Press the Scroll button (12) until <P.14> appears
.
• Press the Enter button (13).
The function of this screen is to activate the remote load/unload relay. To be able to activate this remote
Load/Unload functionality, a physical digital input with function Load/Unload is required.
Once this parameter is activated, the physical digital input can be used to switch the compressor between
Load and Unload.
Contact the Atlas Copco Customer centre for activation of the digital input.
Instruction book