7.16 Calling up/resetting the service timer
Calling up the service timer
Starting from the Main screen:
• Press Scroll button (12) until <d.6> is shown and then press Enter button (13):
This screen shows the unit used <hrs> (or <x1000 hrs>) and the value <1191>. In the example shown, the
compressor has run 1191 hours since the previous service.
Resetting the service timer
After servicing, see section
• Scroll to register screen <d.6> and press Enter button (13).
• The reading (e.g. 4000) will appear.
• Press Enter button (13) and - if a password is set - enter the password.
The icon will flash (indicating that resetting is possible).
• Press Enter button (13) to reset the timer to <0.000> or press the Escape button (14) to cancel the
operation.
Instruction book
2920 7140 90
41