If one of the measurements exceeds the programmed shut-down warning level, this will also be
indicated to warn the operator before the shut-down level is reached.
Service warning
If the service timer exceeds a programmed value, this will be indicated on display (1) to warn the
operator to carry out some service actions.
Automatic restart after voltage failure
The regulator has a built-in function to automatically restart the compressor when the voltage is
restored after voltage failure. This function is deactivated in compressors leaving the factory. If
desired, the function can be activated. Consult the Atlas Copco Customer Centre.
If activated, and provided the regulator was in the automatic operation mode, the
compressor will automatically restart when the supply voltage to the module is restored.
3.2
Control panel
Elektronikon I regulator
Ref.
Name
Function
S3
Emergency stop button
Push button to stop the compressor
immediately in the event of an emergency.
After remedying the trouble, unlock the
button by pulling it out and press reset key
(4).
Only use S3 in case of emergency! Use
the Stop button (1) for normal stopping.
1
Stop button
Push button to stop the compressor. LED
(10) goes out. The compressor will stop
after running in unloaded condition for
about 30 seconds.
2
Start button
Push button to start the compressor. LED
(10) lights up indicating that the regulator is
operative (in automatic operation).
3
Display
Indicates the compressor operating
condition, actually measured values and
programmed parameters.
Instruction book
API451763
27