3.7
Shut-down
Description
The compressor will be shut down in case:
• The temperature at the outlet of the compressor element exceeds the shut-down level
• Of error of the outlet pressure sensor
• Of overload of the drive motor
• Of overload of the fan motor on air-cooled compressors
Compressor element outlet temperature
• If the outlet temperature of the compressor element exceeds the shut-down level (120 ˚C /
248 ˚F, programmable) the compressor will be shut-down, alarm LED (4) will flash,
automatic operation LED (5) will go out and the following screen will appear:
Main screen with shut-down indication, element outlet temperature
flashing
bar
6.6
• Press arrow key (3) until the actual compressor element temperature appears.
Shut-down screen, element outlet temperature
flashing
flashing
˚C
122
The screen shows that the temperature at the outlet of the compressor element is 122 ˚C.
• Switch off the voltage and remedy the trouble.
• After remedying and when the shut-down condition has disappeared, switch on the voltage
and restart the compressor.