bar
6.6
• Press arrow key (2) until <d.02> is shown and then press enter key (1):
<x1000>
10.10
This screen shows the number of motor starts times 1000 (times 1 or if <x1000> lits up times
1000). The number of motor starts is 10100.
3.13 Calling up module hours
Control panel
Starting from the Main screen:
bar
6.6
• Press arrow key (2) until <d.03> is shown and then press enter key (1):
<hrs>
5000
The screen shows the unit used <hrs> and the value <5000>: the module hours of the
compressor are 5000 hours.