• Press enter key (1) on desired pressure band. The load level of the selected pressure band
appears, key (2) can be used to scroll to the unload level.
Loading pressure
bar
6.4
Unloading pressure
bar
7.0
• Press enter key (1) to modify the load level (value starts blinking). A password may be
required. Use keys (2) and (3) to change the load pressue.
• Press enter key (1) to program the new values or press reset key to cancel.
3.20 Modifying pressure band selection
Control panel
Starting from the Main screen:
bar
6.6
• Press arrow key (2) until <P.04> is shown and then press enter key (1). The active pressure
band 1 <Pb.1> is shown on the display.
• Press enter key (1) to modify the pressure band selection (a password may be required).
The active pressure band <Pb.1> starts blinking.
Instruction book
44
API451763