3.28 Activating password protection
Control panel
Important settings such as the setting of the service timer, pressure band setting, control mode
settings,... can be protected by a password.
Starting from the Main screen:
bar
6.6
• Press arrow key (2) until <P.12> and press enter key (1):
<PASS>
• Password <PASS> appears on the screen. Press enter key (1).
• The screen shows the password status on <On> or off <OFF>. Press enter key (1) to
modify.
• Change the value with scroll keys (2) and (3).
• Select <On> and press enter key (1).
• Enter the new password and press enter key (1) to confirm.
• Enter the password again and press enter key (1) to confirm.
• <On> appears on the display. Press reset key to return to the parameter screen.
Lost passwords can not be recovered. Save the password carefully.
Instruction book